about Autohex II Download forum contact

OBD II Fault Code P0403 :

Description of Fault code P0403

EXHAUST GAS RECIRCULATION (EGR) VALVE CIRCUIT OPEN

Possible failuer P0403

  • EGR Actuator (Internal open)
  • EGR Actuator harness (Open)
  • Engine Control Module(ECM) internal circuit.

Diagnostic Procedure using AutoHex II Scan Tool

  • When minute current is drawn on the inactive drive circuit, the open which can't be drawn the current is detected for a set period of time.

Test Conditions using AutoHex tester

  • Continuously

Clear Fault codes Conditions

  • When minute current is drawn on the inactive drive circuit, the open which can't be drawn the current is detected for a set period of time.

MIL Status

  • Check Engine Light ON

Programming BMW F Series


Note:

  • AutoHex II is a professional Auto diagnostic.
  • This fault code is a GERENRIC fault code, some cars may change the meaning of this fault code.
    To get the accurate fault code description you may use AutoHex II

More Fault codes:

OBD II Fault Code P0404
OBD II Fault Code P0405
OBD II Fault Code P0406
OBD II Fault Code P0407
OBD II Fault Code P0408
OBD II Fault Code P0409
OBD II Fault Code P040A
OBD II Fault Code P040B
OBD II Fault Code P040C
OBD II Fault Code P040D
Autohex II Reviews
Autohex II Reviews
Find out Autohex II user's impressions about using this tool for BMW advanced services
AutoHex II
AutoHex II
AutoHex II is your best choice to have full access to dealer functions like coding, adjusting and modules flashing/programming, Contact us for prices
AutoHex Forum
Scan Tool Forum
AutoHex Onboard Diagnostic Forum discusses different subjects, if you want to know more about Mercedes Benz, BMW, VW, Audi, Toyota, Nissan, or other cars, join the forum now
AutoHex II Autohex II For BMW AutoHex II For Kia and Hyundai AutoHex stand alone Mercedes Technical Info